Search results for PED detection in a mantrap

  1. Playbooks: Real-World Scenariosmatch

    Can we add wireless device detection at the mantrap?

    Plain English: Yes, as a supplement to PED policy and lockers. Passive RF detectors only see devices that are transmitting, and the detector itself becomes equipment the AO and CTTA must review. Action plan Know the policy driver. The Secre …

  2. PEDs, Wireless Detection, Telecom & CCTVmatch

    Why PEDs are controlled in SCIFs and SAPFs

    … targeting classified information in SCIFs." It sends readers to the IC Tech Spec for PED restrictions. ICS 705-1 §G.2.a adds that RF transmitters are not allowed in a SCIF unless a competent authority, such as the CTTA, evaluates and mitig …

  3. PEDs, Wireless Detection, Telecom & CCTVmatch

    Vestibule PED detection workflow, step by step

    … SOP and AO approval govern the real one. Step Event System action 1 Person reaches the PED lockers outside the primary entrance and stores devices Signage lists prohibited items 2 Presents a credential at the outer vestibule door ACS grants …

  4. PEDs, Wireless Detection, Telecom & CCTVmatch

    PED lockers, signage and the entry routine

    Lockers and signs are the first PED control and the cheapest one. They give people a place to leave devices before they reach the first SCIF reader, and they make the rule impossible to miss. Element Rule Source Location "Provide lockable m …

  5. PEDs, Wireless Detection, Telecom & CCTVmatch

    SAPF PED items in the DCSA January 2026 checklist

    … which DoD consolidated on 17 January 2025 (Volume 3 cancelled). Several items touch PEDs and wireless. Item What it asks Basis cited F-10 "Have any medical devices or other portable electronic devices (PEDs) been approved for introduction a …

  6. PEDs, Wireless Detection, Telecom & CCTVmatch

    Wiring PED detection into the ACS and door interlock

    … Verify with your AO: No published integration between Hirsch Velocity and a specific PED detector was found. A contact-input design uses standard, verified Mx features. A software integration with any detector platform is a custom design th …

  7. PEDs, Wireless Detection, Telecom & CCTVmatch

    Non-RF screening: ferromagnetic and metal detection

    … a defined response from the security office. Verify with your AO: UFC 4-010-05 addresses PED lockers but contains no PED detection requirement. Whether ferrous or metal screening is used, and how alarms are resolved, is an AO or PSO decisio …

  8. PEDs, Wireless Detection, Telecom & CCTVmatch

    Common PED, wireless, telecom and CCTV traps

    … egress or shunt the IDS Egress must stay free; ACS ranks below IDS Tech Spec 7.A.2.i 7 PED lockers recessed in the perimeter wall or within 10 ft of NSI processing Prohibited placement UFC 3-4.7 8 Standard desk sets, speakerphones or cordle …

  9. PEDs, Wireless Detection, Telecom & CCTVmatch

    What RF detection cannot see

    … alarms Industry, derived Design responses (derived) Layer it. Pair RF detection with PED policy, lockers and signage, and add ferrous or metal screening if the AO wants powered-off devices addressed. Give it time. A vestibule dwell period g …

  10. PEDs, Wireless Detection, Telecom & CCTVmatch

    The 30 June 2023 SECDEF memo: "program for," not "installed by"

    … "Security Review Follow-on Actions" on 30 June 2023. Two of its directions concern PEDs. Direction Memo language Date User certification "Issue policy guidance to ensure all SCIF and SAPF users and occupants certify their adherence to polic …

  11. PEDs, Wireless Detection, Telecom & CCTVmatch

    PED detection products: verified vendor claims compared

    … and companies selling coverage systems (DAS or emergency responder radio) rather than detection. Field note: Before submitting any detector, get the manufacturer's written statement of whether the unit transmits, what network interfaces it …

  12. PEDs, Wireless Detection, Telecom & CCTVmatch

    Tech Spec Chapter 10: approvals, prohibitions and risk levels

    Tech Spec Chapter 10 has four parts: A. Approved Use of PEDs/RCET in a SCIF; B. Prohibitions; C. PED/RCET Risk Levels; D. Risk Mitigation. The chapter title pairs PEDs with "Recording Capabilities and Embedded Technologies" (RCET); the acro …

  13. PEDs, Wireless Detection, Telecom & CCTVmatch

    Government-owned, medical and wearable devices

    … approval. The approval does not transfer to other agencies. 12 FAM 710 Government-owned PEDs (State example) Advance written approval 12 FAM 718.2-1 Medical devices and PEDs (SAP) "Have any medical devices or other portable electronic devic …

  14. PEDs, Wireless Detection, Telecom & CCTVmatch

    Detection sensors are equipment too: review, networks and records

    … AO; customer IT authority Where are logs kept, and who sees them? Logs tie device detections to badge events and times SSO or PSO Choosing the connection style (derived) Contact-closure only. A unit with dry contacts and no Ethernet, such a …

  15. PEDs, Wireless Detection, Telecom & CCTVmatch

    How RF device detection works

    … it raises an alert and, in better systems, estimates where the device is. Three jobs a detection system does Listen passively. The sensors receive and never transmit. That matters in a SCIF: a detector that transmitted would itself be an RF …

  16. Glossarymatch

    Interlocked vestibule (mantrap)

    … interlocks, so each application needs AHJ approval and must never block egress. See: PEDs, Wireless Detection, Telecom & CCTV

  17. PEDs, Wireless Detection, Telecom & CCTVmatch

    Interlocked vestibules and life safety: get the AHJ first

    … still gives one-hand mechanical egress from inside, so a person left inside is not trapped. Emergency exit doors stay alarmed 24/7 with local annunciation (UFC 3-4.6.10). The fire alarm interface is a conductor crossing the perimeter. Coord …

  18. PEDs, Wireless Detection, Telecom & CCTVmatch

    Telephones in SCIFs: TSG-6, TSG-2 and VoIP rules

    Plain English: An ordinary desk phone can pick up room conversation even when it is hung up. SCIF phone rules exist to make sure a phone on the hook is truly deaf, and that the phone system behind it cannot be used to turn a phone into a mi …

  19. PEDs, Wireless Detection, Telecom & CCTVmatch

    Speakerphones, notification, cable TV and building controls

    Beyond telephones, the Fixed Facility Checklist asks about every other system that can carry sound, images or data across the perimeter. None is automatically forbidden. Each must be declared and configured as the AO approves. System What t …

  20. PEDs, Wireless Detection, Telecom & CCTVmatch

    CCTV at the SCIF entrance: Tech Spec 8.E and camera design

    CCTV at a SCIF has one job: help people inside see who is at the door. It supplements access control. It never replaces the lock, the ACS or the IDS, and it must never become a way to see inside. Item Rule Source Purpose CCTV "may be used t …

  21. Traps & Common Failuresmatch

    PED, telecom and CCTV traps

    … TV brought in undeclared FFC F.5 requires an annotated floor plan Declare it Checklist PED lockers recessed in the perimeter or near NSI processing UFC 3-4.7 Lockers outside the primary entrance, placed per UFC UFC Promising RF detection ca …

  22. Glossarymatch

    Portable electronic device (PED)

    Any portable device that can record, store or transmit, such as a phone, smartwatch, fitness tracker or laptop; PEDs are prohibited in SCIFs unless approved under Tech Spec Chapter 10. See: PEDs, Wireless Detection, Telecom & CCTV

  23. Intrusion Detection & UL 2050 / Extent 3match

    Modes of operation: armed, disarmed and maintenance

    … armed-to-disarmed transition. The SCI-cleared administrator sets the maintenance PIN. PEDs may connect for maintenance under SCI-cleared control. Remote diagnostics are logged. 7.B.4 DoD design criteria add two features that are often built …

  24. Intrusion Detection & UL 2050 / Extent 3match

    Sensors: UL 634 Level II switches and UL 639 motion detection

    … Cite Perimeter doors "SCIF perimeter doors shall be protected by an HSS and a motion detection sensor." 7.A.3.a(7) Emergency exit doors "Emergency exit doors shall be alarmed and monitored 24 hours per day." Egress-only doors also need a lo …