Search results for FF-L-2740B vs FF-L-2890

  1. Doors, Locks & Security Containersmatch

    FF-L-2740B combination locks and approved models

    FF-L-2740B, Locks, Combination, Electromechanical (15 Jun 2011, superseding FF-L-2740A of 1997), is the lock that protects unattended national security information on GSA containers, vault doors and SCIF pedestrian door deadbolts. What the …

  2. Doors, Locks & Security Containersmatch

    Approved FF-L-2890 products and the revision question

    Only products on the Qualified Products List may be used as FF-L-2890 lock extensions. The DoD Lock Program posts the current list. QPL-FF-L-2890-5 (21 Mar 2022). Manufacturer and series Types listed Kaba Mas CDX-10 Type VI Lockmasters LKM1 …

  3. Doors, Locks & Security Containersmatch

    GSA vault doors under AA-D-600D

    … min 30 min — Arms, ammunition and explosives only; not for classified 5-B (Ballistic) FF-L-2740B 10 min 30 min 20 hr Ballistic resistant 5-V (Security) FF-L-2740B 10 min 30 min 20 hr For national security information Class 6 (AA-D-600C) F …

  4. Glossarymatch

    FF-L-2740B

    … doors and SCIF door deadbolts; current approved models are the Kaba Mas X-10 and S&G 2740B. See: Doors, Locks & Security Containers

  5. Access Control, Identity & Hirschmatch

    Electric strikes, UL 1034 and the FF-L-2740 lock

    … at night. The two work side by side, and the strike is never what secures an empty SCIF. FF-L-2890C (22 Feb 2019; supersedes FF-L-2890B) defines pedestrian door lock extensions: Types II, IV, VII and VIII provide "fail secure, electric rele …

  6. Doors, Locks & Security Containersmatch

    Electrified hardware: UL 1034 fail-secure strikes and the FF-L-2740 lock

    … a positive engagement, fail secure, and approved under UL 1034 for burglar resistance." FF-L-2890C: Types II, IV, VII and VIII provide "fail secure, electric release capability for use with existing automated building access control systems …

  7. Doors, Locks & Security Containersmatch

    FF-L-2890C pedestrian door device types

    … the door ties into an access control system. Type Door application Trim Access control FF-L-2740B lock I Primary, any swing Lever Stand-alone keypad Yes II Primary, any swing Lever Integrated with building ACS (fail-secure electric release) …

  8. Traps & Common Failuresmatch

    Naming and version traps

    … mechanical combination lock for AA&E; the padlock specs are FF-P-110J and MIL-DTL-43607 FF-L-2740B for classified Primary Specifying the LKM7000 as current Not on QPL-FF-L-2890-5, which lists the LKM10K; treat as legacy (current status unve …

  9. Traps & Common Failuresmatch

    Door and lock traps

    … not defective products." Trap Why it fails Fix Source type Deadlatch where an FF-L-2890 deadbolt is required Tech Spec 3.E sets hardware by door category FF-L-2890 type per door in the schedule Primary Extra standalone or flush deadbolts on …

  10. Access Control, Identity & Hirschmatch

    Secondary and emergency doors: shut the ACS off when unoccupied

    Door type Locking hardware (Tech Spec) ACS rule Primary entrance (3.E.2) FF-L-2890 deadbolt plus an FF-L-2740 combination lock (or FF-L-2740 integrated hardware the AO previously approved) Approved access control device; by-pass keyway allo …

  11. Reference Librarymatch

    Locks, containers & federal specs

    … products list PDFs DoD Lock Program: Combination Locks NAVFAC EXWC Current Approved FF-L-2740B locks and related door hardware FF-L-2740B, Locks, Combination, Electromechanical GSA 15 Jun 2011; Amendment 2, 21 Aug 2018 Combination locks for …

  12. Playbooks: Real-World Scenariosmatch

    The fire marshal wants magnetic locks on the SCIF door

    … The SCIF's goal is a door that stays locked when power or the access system fails. FF-L-2890 hardware is built to satisfy both, and a maglock satisfies neither well. Action plan Meet early with the AHJ and bring cut sheets. The DoD Lock Pro …

  13. Doors, Locks & Security Containersmatch

    The three SCIF perimeter door categories

    … as the main entrance." GSA-approved pedestrian door deadbolt meeting the most current FF-L-2890 (or previously AO-approved FF-L-2740 installations) plus a combination lock meeting the most current FF-L-2740 "An approved access control devic …

  14. PEDs, Wireless Detection, Telecom & CCTVmatch

    Interlocked vestibules and life safety: get the AHJ first

    … 294 listed? SCIF-specific coordination (derived) The egress side of each SCIF door keeps FF-L-2890 one-motion mechanical free egress. Fire alarm and power loss release the interlock logic, as the AHJ approves. The FF-L-2740 lock and FF-L-28 …

  15. Doors, Locks & Security Containersmatch

    The DoD Lock Program and technical support hotline

    … Security Facts Newsletters. Posted federal specifications and Qualified Products Lists (FF-L-2740B, FF-L-2890C, AA-D-600D, AA-V-2737 and others). Mirror copies of ICD 705, ICS 705-1, ICS 705-2, the Tech Spec v1.5.1 and UFC 4-010-05. Disposa …

  16. Penetrations, Utilities & Life Safetymatch

    Egress doors, delayed egress and panic hardware

    Getting people out quickly and keeping intruders out are reconciled at the door hardware. The FF-L-2890C device types were written with that conflict in mind. Topic Guidance Source Egress-only doors FF-L-2890 exit-only device; no exterior h …

  17. Glossarymatch

    Electromechanical combination lock

    A dial-operated lock with electronic combination processing, such as the Kaba Mas X-10 or S&G 2740B; every lock currently approved under FF-L-2740B is of this type. See: Doors, Locks & Security Containers

  18. RF Shielding, Penetrations & Installer Methodsmatch

    RF doors: knife-edge, finger stock and gaskets

    … 3.E.5.g: "SCIF Perimeter doors shall meet TEMPEST requirements per CTTA guidance." The FF-L-2890 deadbolt, electrified lock, REX, balanced magnetic switch and card reader must all be installed without disturbing the knife-edge or finger sto …

  19. Construction Security & Build Sequencematch

    Phase 2: design

    … flute infill. Door schedule with STC assembly ratings 5 points above the target and the FF-L-2890 type for each door; vestibule. Window treatments; the 18-ft zone marked on elevations. Penetration schedule listing every duct, pipe, conduit …

  20. Glossarymatch

    Class 5-V vault door

    The AA-D-600D security vault door fitted with an FF-L-2740B lock for national security information; the Tech Spec requires a GSA-approved Class 5 vault door on every vault. See: Doors, Locks & Security Containers

  21. Access Control, Identity & Hirschmatch

    Integrator traps for access control and door hardware

    # Trap Basis 1 Treating the electric strike as the SCIF lock. An unoccupied SCIF is secured by the FF-L-2740 lock throwing the FF-L-2890 deadbolt, with the IDS armed. ICS 705-1 §G.2.b; Tech Spec 3.E.2–3 2 Fail-safe strikes or maglocks. D …

  22. Traps & Common Failuresmatch

    Top 25 inspection killers

    … UFC 10 Deadlatch, extra deadbolts or exterior hardware on exit-only door Tech Spec 3.E FF-L-2890 type per door Primary 11 Exit-only door not alarmed 24/7 with local annunciator Tech Spec 3.E.4 Alarm and annunciate Primary 12 Electric strike …

  23. Penetrations, Utilities & Life Safetymatch

    Accessibility: ADA and ABA in secure spaces

    … occupied space. DoD design criteria reference the Architectural Barriers Act (ABA), and FF-L-2890C hardware is written to ADA and UFAS operating requirements. The AHJ confirms which accessibility standard governs the project. Where accessib …

  24. Start Here: How SCIF Security Fits Togethermatch

    The object model

    … any) Security systems Perimeter: walls, floor, ceiling, windows, vault Doors & locks: FF-L-2890 hardware, FF-L-2740 lock IDS: UL 2050 Extent 3, PCU, monitoring, response force ACS: two or more technologies while occupied Acoustics: Sound Gr …

  25. Access Control, Identity & Hirschmatch

    The role of access control in a SCIF

    … occupied hours and logs entries ICS 705-1 §G.2.b; Tech Spec Ch. 8 FF-L-2740 lock on FF-L-2890 hardware Secures the primary door when the SCIF is unoccupied Tech Spec 3.E.2 IDS (UL 2050 Extent 3) Detects intrusion when unoccupied Tech Spec …